XCSDMP790L01M12

Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 2 NC, staggered, M12 0.15 m

arrow

Commercialized

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Coded magnetic switch
Component name
XCSDMP
Design
Rectangular, standard
Size
88 x 25 x 13 mm
Contacts type and composition
2 NC
Contact operation
Staggered
Material
Plastic
Electrical connection
Connector on flying lead
Connector type
M12
Cable length
0.15 m
Number of poles
2
Approach directions
3 directions
[Ue] rated operational voltage
24 V DC
[Ui] rated insulation voltage
100 V DC
[Sa] assured operating distance
8 mm
[Sar] assured tripping distance
20 mm
Maximum [Ie] rated operational current
100 mA
[Uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60947-5-1
Resistance across terminals
10 Ohm
Short-circuit protection
500 mA external cartridge fuse type gG (gl)
Contacts material
Rhodium
Electrical durability
1200000 cycles
Maximum switching voltage
100 V DC
Switching capacity in mA
0.1...100 mA
Insulation resistance
1000 MOhm
Breaking capacity
10 VA
Switching frequency
150 Hz
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure material
Thermoplastic PBT
Cable material
PVC
Depth
13 mm
Height
88 mm
Width
25 mm
Net weight
0.18 kg
Standards
CSA C22.2 No 14
ISO 12100
UL 508
IEC 60204-1
IEC 60947-5-1
ISO 14119
Product certifications
UL
CSA
Protective treatment
TH
Ambient air temperature for operation
-25…85 °C
Ambient air temperature for storage
-40…85 °C
Vibration resistance
10 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance
30 gn for 11 ms conforming to IEC 60068-2-27
Maximum sensitivity to magnetic fields
0.3 mT
Electrical shock protection class
Class II conforming to IEC 61140
IP degree of protection
IP67 conforming to IEC 60529
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.000 cm
Package 1 Width
4.000 cm
Package 1 Length
17.000 cm
Package 1 Weight
114.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
4.842 kg
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Expand all

Related products & accessoires

img
XZCP0941L2

Pre wired connectors XZ, straight female, M8, 4 pins, cable PUR 2 m

img
XZCP29P11L2

Pre wired connectors XZ, straight female, M12, 8 pins, cable PUR 2 m

img
XZCP1141L2

Pre wired connectors XZ, straight female, M12, 4 pins, cable PUR 2 m

img
XZCP29P12L2

Pre wired connectors XZ, straight female, M12, 8 pins, cable PUR 2 m

Back to top

arrow