Materials in contact with fluid
CERAMIC
FLUOROCARBON FPM
STAINLESS STEEL AISI 316L
Operating position
ANY POSITION
Protection type
LOAD SHORT CIRCUIT
REVERSE POLARITY
Electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz,
radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz,
electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact,
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm,
immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz,
electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
0 5 PT OF MEASURING RANGE
Accuracy
0 1 PT OF THE MEASURING RANGE
Drift of the sensitivity
0 02 PT OF MSRG RANGE D K
Drift of the zero point
0 02 PT OF MSRG RANGE D K
Repeat accuracy
0 25 PT OF MSRG RANGE