XMPA12C2141

Pressure sensors XM, pressure sensor XMP, 12 bar, G 1/4 female, 3 NC, without control type

arrow

Commercialized

green premium

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Pressure sensor type
Electromechanical pressure sensor
Pressure sensor name
XMP
Pressure rating
12 bar
Fluid connection type
G 1/4 (female) conforming to ISO 228
Controlled fluid
Air (0…70 °C)
Fresh water (0…70 °C)
Sea water (0…70 °C)
Cable entry
2 entries incorporating Pg 13.5 plastic cable gland, cable outer diameter: 9…13 mm conforming to NF C 68-300
Contacts type and composition
3 NC snap action
Product specific application
-
Pressure switch type of operation
Regulation between 2 thresholds
Electrical connection
Screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm²
Electrical circuit type
Power circuit
Scale type
Adjustable differential
Local display
Without
Sale per indivisible quantity
1
Adjustable range of switching point on falling pressure
0.3…10.3 bar
Adjustment range high setting
1.3…12 bar
Possible differential minimum at low setting
1 bar
Possible differential minimum at high setting
1.7 bar
Possible differential maximum at high setting
8.4 bar
Destruction pressure
30 bar
Type of decompression valve
Without
Control type
Without
Terminal block type
6 terminals
Pressure actuator
Diaphragm
Materials in contact with fluid
Canvas covered nitrile
Chromated zinc alloy
Enclosure material
PA impregnated with fibreglass
Operating position
Any position
Maximum operating rate
10 cyc/mn
Repeat accuracy
3.5 %
[Ui] rated insulation voltage
500 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Electrical durability
1000000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
500000 cycles 3 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
600000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4, 230 V AC 3 phases
700000 cycles 2.2 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
Mechanical durability
1000000 cycles
Setting
Nut
Terminals description ISO n°1
(3-4)NC
(1-2)NC
(5-6)NC
Depth
98 mm
Height
106 mm
Width
57 mm
Product certifications
EAC
Standards
CE
IEC 60947-4-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
3 gn conforming to IEC 60068-2-6 (f = 10…500 Hz)
Shock resistance
50 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 60536
IP degree of protection
IP54 conforming to IEC 60529
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.400 cm
Package 1 Width
11.400 cm
Package 1 Length
16.800 cm
Package 1 Weight
520.000 g
Unit Type of Package 2
CAR
Number of Units in Package 2
8
Package 2 Height
14.600 cm
Package 2 Width
29.000 cm
Package 2 Length
38.400 cm
Package 2 Weight
4.464 kg
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Expand all

Technical Drawings

Dimensions

Without Decompression Valve

epds
  • ØA = G 1/4
  • (1) 2 tapped entries for Pg 13.5

Minimum Mounting Clearance

epds
  • ØA = G1/4
  • (1) Minimum clearance zone for screwing-on pressure switch at point A

Wiring Diagram

Terminal Connections

epds

Curves

Operating Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential

Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • PH : High point
  • PB : Below point