Local signalling
Without pilot light
Trigger cable maximum length
30 m
Cover material
Stainless steel
Reset
By booted push-button
Contacts type and composition
2 NC + 1 NO
Contact operation
Slow-break
Trigger cable anchor point
RH or LH side
Connections - terminals
Screw clamp terminal, 1 x 0.34...1 x 1 mm²
Screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
Tightening torque
0.8…1.2 N.m
Cable entry number
3 tapped entry for Pg 13.5 cable gland
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data
B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
Mechanical durability
800000 cycles
Distance between cable supports
5 m
[Ie] rated operational current
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
6 A
[Ui] rated insulation voltage
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
[Uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
Positive opening
With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Short-circuit protection
6 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description ISO n°1
(21-22)NC
(31-32)NC
(13-14)NO