Mechanical durability
300 cycles
Cable entry number
2 conduit entries for 3/4"-14 NPT conforming to UL 508
Electrical durability
100 cycles, operating rate <60 cyc/mn
Electrical connection
Screw-clamp terminals, clamping capacity: 10 AWG
Electrical circuit type
Power circuit
Contacts type and composition
2 NO, snap action, DPST-DB, Form XX
Terminals description ISO n°1
Line-load-load-line
Contact operation
Contacts open on liquid rise
[Ui] rated insulation voltage
575 V conforming to UL 508
Short-circuit protection
20 A cartridge fuse, type gG
Controlled fluid
Fresh water at specific gravity of 0.85 in or higher, sea water at specific gravity of 0.85 in or higher, hydraulic oil at specific gravity of 0.85 in or higher, corrosive fluid at specific gravity of 0.85 in or higher
Motor power kW
1.5 kW (2 hp) at 115 V AC, 1 phase, 2.2 kW (3 hp) at 115 V AC, 3 phases, 2.2 kW (3 hp) at 230 V AC, 1 phase, 3.7 kW (5 hp) at 230 V AC, 3 phases, 0.75 kW (1 hp) at 460 V AC, 3 phases, 0.75 kW (1 hp) at 475 V AC, 3 phases, 0.18 kW (0.25 hp) at 32 V DC, 0.37 kW (0.5 hp) at 115 V DC, 0.37 kW (0.5 hp) at 230 V DC
Terminal block type
4 terminals
Float movement
Variable adjustable
Product weight
4.08 livre