Minimum torque for tripping
190 ozf.in
Maximum actuation speed
90 ft/min with 45° cam angle, levers only, 130 ft/min with 30° cam angle, levers only
Cable entry
1 entry for 1/2" - 14 NPT conforming to ANSI B1.20.1
Contact code designation
A600, AC (Ue = 600 V) Ie = 5 A conforming to NEMA rating designation, A600, AC (Ue = 480 V) Ie = 6.25 A conforming to NEMA rating designation, A600, AC (Ue = 240 V) Ie = 12.5 A conforming to NEMA rating designation, A600, AC (Ue = 120 V) Ie = 20 A conforming to NEMA rating designation, P600, DC (Ue = 600 V) Ie = 0.2 A conforming to NEMA rating designation, P600, DC (Ue = 250 V) Ie = 1 A conforming to NEMA rating designation, P600, DC (Ue = 120 V) Ie = 5 A conforming to NEMA rating designation
Contact sequence number
2
Repeat accuracy
+/- 0.03 %
Electrical connection
Screw-clamp terminals AWG 22...AWG 12
Terminals description ISO n°1
(1-2) left side contact
(3-4) right side contact
Contact operation
Snap action
Contacts material
90/10 AgCdO on copper backing stationary contact, silver on steel backing moveable contact
CCW operation contacts
1 NC + 1 NO
Contacts usage
Not applicable
CW operation contacts
1 NC + 1 NO
[Uimp] rated impulse withstand voltage
2.5 kV AC for 1 minute conforming to CE, 2.2 kV AC for 1 minute conforming to UL, 2.64 kV AC for 1 minute conforming to CSA
[Ui] rated insulation voltage
600 V (pollution degree 3) conforming to IEC 60947-1, 600 V (pollution degree 3) conforming to UL 508, 600 V (pollution degree 3) conforming to CSA C22.2 No 14
[Ithe] conventional enclosed thermal current
20 A
Electrical shock protection class
Class 0 conforming to IEC 61140
Short-circuit protection
20 A Bussmann class CC KTK-R-20 non-time delay