Mechanical durability
10000000 cycles
Minimum force for tripping
0.1 N
Maximum actuation speed
1.5 m/s
Electrical durability
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical connection
Male connector M12, 5 pins
Positive opening
With, conforming to IEC 60947-5-1 Annex K
Positive opening minimum force
0.5 N
Contacts insulation form
Zb
Contacts type and composition
1 NC + 1 NO
Contact operation
Snap action
[Uimp] rated impulse withstand voltage
0.8 kV conforming to IEC 60664, 0.8 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
60 V (pollution degree 3) conforming to IEC 60947-5-1
[Ie] rated operational current
0.22 A at 50 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A, 3 A at 50 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
4 A
Resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
Electrical shock protection class
Class I conforming to IEC 61140, class I conforming to NF C 20-030
Short-circuit protection
4 A cartridge fuse, type gG