Actuator force for extraction
20 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry number
1 tapped entry for M20 x 1.5 cable gland (included) 7-13 mm
Contact code designation
A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1, A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1, Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1, Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
Electrical connection
Terminal
Positive opening
With NC contact
Contacts type and composition
1 NC + 2 NO
Contact operation
Slow-break, break before make
Operating rate
10 cyc/mn for maximum durability
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to EN/IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ithe] conventional enclosed thermal current
10 A
Electrical shock protection class
Class I conforming to EN/IEC 60536
Short-circuit protection
10 A cartridge fuse type gG (gl)
Clamping connection capacity
1 x 0.5...2 x 1.5 mm² with or without cable end