XCSMP59L2

Safety switch XCSMP, plastic, 1NC+1NO, slow break, pre-cabled 2 m

END OF COMMERC ANNOUNCED End of commercialization date : December 31st 2026 End of service date : December 31st 2026

XCSMP59L2 is replaced by the following product:

img

Quantity :  1

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Safety switch
Component name
XCSMP
Design
Miniature
Sensor design
Miniature
ETIM classification
ETIM 9 - EC002593 - Position switch with guard locking
Head type
Key operated fixed head
Material
Plastic
Body material
PA (polyamide)
Head material
PA (polyamide)
Number of poles
2
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Locking options description
Without locking of actuator
Product certifications
CSA
cUL
UL
Standards
CSA C22.2 No 14
EN 1088/ISO 14119
IEC 60204-1
IEC 60947-5-1
ISO 12100
UL 508
Indivisible sale quantity
1
Actuator force for extraction
8 N
Actuator forcible withdrawal rtc
8 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.05 m/s
Electrical connection
Pre-cabled
Cable length
2 m
Cable composition
4 x 0.5 mm²
Positive opening
With NC contact
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, break before make
Operating rate
20 cyc/mn for maximum durability
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ie] rated operational current
0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.75 A at 240 V, AC-15, C300 conforming to IEC 60947-5-1, 1.5 A at 120 V, AC-15, C300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
2.5 A
Electrical shock protection class
Class II conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Insulation
Double insulated
Width
15 mm
Depth
30 mm
Product weight
0.11 kg
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-25…80 °C
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
6 gn (f= 10-55 Hz) conforming to IEC 60068-2-6
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
JP (Japan)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916047439
Package 1 height
2 cm
Package 1 width
21 cm
Package 1 length
20.5 cm
Package 1 weight
0.22 kg
Unit type of package 2
S03
Number of units in package 2
20
New Package 2 GTIN 14
13666916047436
Package 2 height
30 cm
Package 2 width
30 cm
Package 2 length
40 cm
Package 2 weight
5.126 kg
Unit type of package 3
BAG
Number of units in package 3
1
New Package 3 GTIN 14
23666916047433
Package 3 height
2 cm
Package 3 width
20.5 cm
Package 3 length
21 cm
Package 3 weight
0.22 kg

Expand all

Documents & Downloads

Document name
Date
Size
Document name
Date
Size
Document name
Date
Size

Back to top

arrow