XMLA001R2C11

Pressure switch, XMLA, pressure range 1 bar, fixed scale, 1CO, 1 threshold

END OF COMMERCIALISATION End of commercialization date : April 20th 2022 End of service date : April 20th 2022

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Pressure sensor type
Electromechanical pressure sensor
Product or component type
Electromechanical pressure sensor
Device short name
XMLA
Product specific application
Not applicable
ETIM classification
ETIM 9 - EC000243 - Pressure switch
Enclosure material
Zinc alloy
Materials in contact with fluid
304L stainless steel
FPM, FKM
steel
Pressure switch type of operation
Detection of 1 single threshold
Operating position
Any position
Pressure sensor size
1 Bar
Maximum permissible accidental pressure
2.25 Bar
Maximum permissible pressure - per cycle
1.25 Bar
Destruction pressure
4.5 Bar
Pressure actuator
Diaphragm
Controlled fluid
Air (0-160 °C), hydraulic oil (0-160 °C)
Fluid connection type
G 1/4 (female) conforming to ISO 228
Local display
With
Scale type
Fixed differential
Setting
External
Product certifications
BV
CCC
CSA
LROS (Lloyds register of shipping)
UL
Standards
CE
CSA C22.2 No 14
IEC 60947-5-1
UL 508
Mechanical durability
4000000 cycles
Repeat accuracy
2 %
Electrical connection
1 male connector EN 175301-803-A (ex DIN43650), 4 pins
Electrical circuit type
Control circuit
Contacts type and composition
1 C/O
Contacts material
Silver contacts
Terminals description ISO n°1
(13-14-11-12)OF
Auxiliary contacts operation
Snap action
Operating rate
120 cyc/mn
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[In] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to IEC 60947-5-1, 0.1 A, R300, DC-13 (Ue = 250 V) conforming to IEC 60947-5-1
Resistance across terminals
25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A
Electrical shock protection class
Class I conforming to IEC 1140, class I conforming to IEC 536, class I conforming to NF C 20-030
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Adjustable range of switching point on rising pressure
0.0300…1.0000 bar
Adjustable range of switching point on falling pressure
0.0100…0.9600 bar
Natural differential at low setting
0.02 bar (+/- 0.01 bar)
Natural differential at high setting
0.04 bar (+/- 0.01 bar)
Height
162 mm
Width
110 mm
Depth
110 mm
Product weight
2.57 kg
IP degree of protection
IP65 conforming to IEC 60529
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Shock resistance
30 gn conforming to IEC 60068-2-27
Vibration resistance
2 gn conforming to IEC 60068-2-6 (f = 30-500 Hz)
Protective treatment
TC standard version
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
CZ (Czech Republic)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916142677
New Package 2 GTIN 14
13666916142674
New Package 3 GTIN 14
23666916142671

Expand all

Technical Drawings

Dimensions

epds
  • (1) 1 fluid entry, tapped G1/4 (BSP female)
  • (2) EN 175301-803-A connector

Wiring Diagram

Terminal Model

epds

Wiring Diagram

Vacuum Switch Connector Pin View

epds
  • (1) 11 and 13
  • (2) 12
  • (3) 14

Operating Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
epds
  • (y) Rising pressure
  • (x) Falling pressure
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • (2) Non adjustable value
  • PH : High point
  • PB : Below point

Expand all

Documents & Downloads

Document name
Date
Size

Expand all

Related products & accessories

Back to top

arrow