XMLK200P2C23

Pressure sensor, XMLK, pressure range 0 to 200 psi, output 4-20 mA, 1/4 NPT, DIN connector

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Pressure sensor type
Pressure transmitter
Product or component type
Electronic pressure sensors
Pressure sensor name
XMLK
ETIM classification
ETIM 9 - EC000243 - Pressure switch
Materials in contact with fluid
Ceramic
nitrile (NBR)
stainless steel type AISI 303
Operating position
Any position
Maximum permissible accidental pressure
400 PSI
Destruction pressure
600 PSI
Controlled fluid
Air (0-80 °C), fresh water (0-80 °C)
Fluid connection type
1/4" - 18 NPT (male)
Local display
Without
Diameter
36 mm
Scale type
Fixed differential
Product certifications
CSA C22-2 No 14
RCM
UL 508
Standards
CE
IEC 61326-2-3
Indivisible sale quantity
1
Quantity per set
Set of 1
Type of packing
Individual
Mechanical durability
10000000 cycles
Repeat accuracy
+/- 1 % de la plage de mesure
Electrical connection
1 male connector EN 175301-803-A (ex DIN43650) 4 pins
Electrical circuit type
Control circuit
[Us] rated supply voltage
24 V DC SELV (voltage limits: 8-33 V)
[Uimp] rated impulse withstand voltage
0.5 kV
Current consumption
20 mA
Protection type
Load short-circuit
reverse polarity
Type of output signal
Analogue
Analogue output function
4...20 mA, 2-wire
Response time on output
< 5 ms
Measurement accuracy
+/- 1 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,04 % of measuring range/°K
Drift of the zero point
+/- 0,03 % of measuring range/°K
Length
65.5 mm
Product weight
0.11 kg
IP degree of protection
IP65 conforming to IEC 60529
NEMA degree of protection
NEMA 4
Ambient air temperature for operation
0…80 °C
Ambient air temperature for storage
-25…80 °C
Shock resistance
25 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
20 gn (f = 9-2000 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 6 kV contact, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, immunity to magnetic fields conforming to IEC 61000-4-8 30 A/m 50 Hz
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
CH (Switzerland)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916022863
Package 1 height
4.2 cm
Package 1 width
6.5 cm
Package 1 length
9.5 cm
Package 1 weight
0.11 kg
Unit type of package 2
S01
Number of units in package 2
24
New Package 2 GTIN 14
13666916022860
Package 2 height
15 cm
Package 2 width
15 cm
Package 2 length
40 cm
Package 2 weight
3.328 kg
New Package 3 GTIN 14
23666916022867

Expand all

Technical Drawings

Dimensions

epds

Wiring Diagram

2-Wire Technique (4-20 mA)

epds
  • (a) I out

Output Curves

epds

Expand all

Documents & Downloads

Document name
Date
Size
Document name
Date
Size
Document name
Date
Size

Back to top

arrow