XUBLAPCNL2R

photo-electric sensor - XUB - receiver - laser - Sn 100m - 12..24VDC - cable 2m

END OF COMMERCIALISATION End of commercialization date : December 08th 2020 End of service date : December 08th 2020

XUBLAPCNL2R is replaced by the following product:

img

Quantity :  1

Expand all

Datasheet

Range of product
Telemecanique Photoelectric sensors XU
Sensor name
XUB
Series name
Application material handling
Product specific application
Not applicable
Enclosure material
PBT
Electronic sensor type
Photo-electric sensor receiver
Sensor design
Cylindrical M18
Electrical connection
Cable
Material
Plastic
Wiring technique
3-wire
Detection system
Thru beam
Emission
Red laser thru beam class 1 670 nm conforming to IEC 60825-1
Discrete output function
1 NO or 1 NC programmable
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
Type of output signal
Discrete
Supply circuit type
DC
Discrete output type
PNP
Delay response
0.4 MILLISECOND
Current consumption
25 mA no-load
Output type
Solid state
Switching capacity in mA
<= 100 mA (overload and short-circuit protection)
Lens material
PMMA
Status LED
1 LED (green) for supply on, 1 LED (yellow) for output state, 1 LED (red) for stability
Sensing range
> 30 m
Maximum voltage drop
<1.5 V (closed state)
Delay first up
80 MILLISECOND
Delay recovery
0.4 MILLISECOND
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protection
IP67 double insulation conforming to IEC 60529
Vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
3.6 CENTIMETER
Package 1 width
7 CENTIMETER
Package 1 length
13 CENTIMETER
Package 1 weight
93 GRAM
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expand all

Technical Drawings

Dimensions

epds

Wiring Schemes

PNP

epds
  • (+) BN : Brown
  • (-) BU : Blue
  • (Output) BK : Black

Curves

Detection Curve (Set to Infinity)

epds

Curves

Excess Gain Curve

epds
  • (X) Distance (m)
  • (Y) Gain

Curves

Standard Curve

epds
  • (X) Distance (m)
  • (Y) Gain
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)

Curves

Detection Limit Curve

epds
  • (X) Distance (m)
  • (Y) Gain
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)

Expand all

Documents & Downloads

Back to top

arrow